S-4.1.1, r. 2 - Educational Childcare Regulation

Full text
32. The permit holder must ensure that the play area
(1)  have at least one window that remains unobstructed at all times and allows a general view of the play area;
(2)  if the play area is situated in part below ground level, all the bases of the windows referred to in paragraph 6 must be not more than 1.20 m from the floor and be situated entirely above ground level;
(3)  have a minimum floor/ceiling clearance of 2.30 m over at least 75% of its net area and a minimum floor/ceiling clearance of at least 2.10 m at any given point in that area;
(4)  have walls covered with smooth, washable materials;
(5)  have floors covered with a washable material other than carpeting and that are not concrete, ceramic, terrazzo or other similar material;
(6)  have windows opening directly to the outside with a glass area that is never less than 10% of the floor area of a room. A windowless room is considered to be part of an adjoining room with windows provided that 60% of the common wall is entirely open; if any part of one of those rooms is more than 6 m from a source of natural light, the minimum glass area lighting the room must be equal to at least 15% of the total floor area;
(7)  be equipped with an artificial lighting system providing a minimum light level of 320 lux measured 1 m above the floor; and
(8)  be maintained at a relative humidity of at least 30% in the winter.
O.C. 582-2006, s. 32; O.C. 1314-2013, s. 15; O.C. 1464-2022, s. 2.
32. The permit holder must ensure that the play area
(1)  have a window that remains unobstructed at all times through which the children may be viewed;
(2)  have, on the average, at least half of its floor/ceiling height above ground level, or have windows referred to in paragraph 6 that are entirely above ground level and whose bases are not more than 1.2 m from the floor;
(3)  have a minimum floor/ceiling clearance of 2.30 m over at least 75% of its net area and a minimum floor/ceiling clearance of at least 2.10 m at any given point in that area;
(4)  have walls covered with smooth, washable materials;
(5)  have floors covered with a washable material other than carpeting and that are not concrete, ceramic, terrazzo or other similar material;
(6)  have windows opening directly to the outside with a glass area that is never less than 10% of the floor area of a room. A windowless room is considered to be part of an adjoining room with windows provided that 60% of the common wall is entirely open; if any part of one of those rooms is more than 6 m from a source of natural light, the minimum glass area lighting the room must be equal to at least 15% of the total floor area;
(7)  be equipped with an artificial lighting system providing a minimum light level of 320 lux measured 1 m above the floor; and
(8)  be maintained at a relative humidity of at least 30% in the winter.
O.C. 582-2006, s. 32; O.C. 1314-2013, s. 15.
32. A play area must
(1)  have a window that remains unobstructed at all times through which the children may be viewed;
(2)  have, on the average, at least half of its floor/ceiling height above ground level, or have windows referred to in paragraph 6 that are entirely above ground level and whose bases are not more than 1.2 m from the floor;
(3)  have a minimum floor/ceiling clearance of 2.30 m over at least 75% of its net area and a minimum floor/ceiling clearance of at least 2.10 m at any given point in that area;
(4)  have walls covered with smooth, washable materials;
(5)  have floors covered with a washable material other than carpeting and that are not concrete, ceramic, terrazzo or other similar material;
(6)  have windows opening directly to the outside with a glass area that is never less than 10% of the floor area of a room. A windowless room is considered to be part of an adjoining room with windows provided that 60% of the common wall is entirely open; if any part of one of those rooms is more than 6 m from a source of natural light, the minimum glass area lighting the room must be equal to at least 15% of the total floor area;
(7)  be equipped with an artificial lighting system providing a minimum light level of 320 lux measured 1 m above the floor; and
(8)  be maintained at a relative humidity of at least 30% in the winter.
O.C. 582-2006, s. 32.